MODEL MP-900, MP-1000 & MP-2000
General Features Include:
1.  Pulse or normal mode operation.
2.  Automatic Demag cycle.
3.  All electronic control.
4.  Recessed Panel meter and controls.
5.  Forced air cooling.
6.  Either End output cable connectors.
7.  Non-Mar chassis runners
8.  Heavy duty parts and chassis
9.  Powder coat gloss finish.
10.No cable change for AC to DC output
11.Easy line voltage conversion on all
except MP-900 models.
12.Remote control
13.AC and DC meter calibration
adjustments
14.International line voltage
operation available
15.Digital Meter standard
Analog Meter optional
16.Patents Pending on Pulse Mode
MP-900
Output - AC and DC Avg. AMPS
Duty Cycle at maximum output
Normal Mode = 20 seconds ON - 2 minutes OFF
Pulse Mode    = 1 hour ON - 30 minutes OFF             
Weight             =  44 lbs. (20kg)
Size H.xW.xD.= 8x11x14 inches(203x280x356mm)
Input
VAC
Input Amps
Normal
Pulse
120
35
12
240
17
6
MP-900
MP-1000
Output - AC and DC Avg. Amps
Cable
Length
20"
6.1m
30'
9.1m
40'
12.2m
50'
15.2m
60'
18.2m
80'
24.4m
MP-1000
1000
900
700
600
500
400
Duty Cycle at maximum output
Normal mode =  20 seconds ON -30 seconds OFF
Pulse mode    =  2 hours ON - 30 minutes OFF
Size H.xW.xD.= 8x11x20 inches(203x280x508mm)
Model
Input
VAC
Input Amps
Weight
Normal
Pulse
MP-1000
120/240
40/20
12/6
60lbs
(27kg)
MP-1000
MP-2000
Output - AC and DC Avg. AMPS
Duty Cycle at maximum output
Normal mode    =  20 seconds ON - 30 seconds OFF
Pulse mode       =  2 hours ON - 30 minutes OFF
Size H.xW.xD.= 10x10x24 inches (254x254x610mm)
Model
Input
VAC
Input Amps
Weight
Normal
Pulse
MP-2000
240/480
80/40
24/12
120lbs (54kg)
MP-2000S
240/480
100/50
48/24
122lbs (55kg)
MP-2000
MP-2000S
Cable Length
20'
6.1m
30'
9.1m
40'
12.2m
50'
15.2m
Avg. Amps
900
800
600
500
TSI Price List
Cable
Length
20'
6.1m
30'
9.1m
40'
12.2m
60'
18.2m
80'
24.4m
100'
30.4m
MP-2000
2000
1800
1400
1000
800
700
MP-2000S
2000
2000
2000
1600
1400
1200
MP-900. 1000, 2000 Flier
PDF